18 research outputs found

    Medição do volume de ar em hidrômetro residencial: resultados preliminares

    Get PDF
    Introduction: This article was created by the 2015research for the Electronics’ Engineering Degree of the University of Santa Catarina’s department (Brazil). Most systems that measure water and are used in residences can register the air flow that may be present in the distribution system. This problem is hard to measure, since it’s a combination of liquid and gas. The purpose of this article is to identify and quantify the sensibility of residential hydrometers to the air volume registered. Methodology: To accomplish it, an experimental hydraulic circuit was developed, and sensors were deployed to monitor the water entry and exit of the system, composed by two warehouses. One warehouse stored water for the circulation of the hydraulic drainage, while the other stored the total amount of water in the system. The water level in the storehouses is controlled with ultrasonic and potentiometer sensors. A spinner is used to estimate the total water volume that enters the system by measuring its volumetric flow. Results: The results show that the hydrometer is very sensible to the air flow and that it can measure up to 44% of air in the air/water combination. The difference in the estimated water volume in the spinner and in the hydrometer was of 3,7 liters. Conclusions: The hydrometer is especially sensible to air presence in the residential hydraulic pipelines under normal conditions of a nominal flow of approximately 1,5 m3 /h.Introducción: este artículo es resultado de la investigación realizada en el 2015 para la Licenciatura en Ingeniería electrónica de la Universidad del Estado de Santa Catarina (Brasil). Muchos sistemas de medición de agua utilizados en residencias pueden registrar el paso de aire que puede estar presente en el sistema de distribución. Este problema es complejo de medir, pues se trata de una mezcla entre líquido y gas. Este artículo tiene como propósito identificar y cuantificar la sensibilidad de hidrómetros residenciales en cuanto al volumen de aire que se registra. Metodología: para ello, se desarrolló un circuito hidráulico experimental, en el que se utilizaron sensores para monitorear la entrada y salida de agua y aire en el sistema, compuesto por dos depósitos. Uno de ellos almacena agua para la circulación del drenaje hidráulico armado y el otro almacena el agua total del sistema. El control del nivel del agua en los depósitos se hace por sensores: ultrasónico y potenciométrico. Un rotámetro se usa para estimar el volumen total del agua que entra en el sistema desde la lectura de su flujo volumétrico. Resultados: los resultados obtenidos mostraron que el hidrómetro tiene una sensibilidad al flujo de aire que no se puede despreciar y llega a medir hasta 44% de aire en la mezcla de aire y agua. El error entre el volumen estimado de agua por el rotámetro y lo que se lee en el hidrómetro fue de 3,7 litros. Conclusión: el hidrómetro es significamente sensible a la presencia de aire en las tuberías hidráulicas residenciales, bajo las condiciones normales de un flujo nominal de aproximadamente 1,5 m3 /h.Introdução: este artigo é resultado de pesquisa realizada em 2015 para a Licenciatura em Engenharia Elétrica pela Universidade do Estado de Santa Catarina. Muitos sistemas de medição de água utilizados em residências podem registrar a passagem de ar que pode estar presente no sistema de distribuição. Esse problema é complexo de medir, pois se trata de uma mistura entre líquido e gás. Este artigo tem como objetivo identificar e quantificar a sensibilidade de hidrômetros residenciais quanto ao volume de ar que é registrado. Metodologia: para isso, foi desenvolvido um circuito hidráulico em bancada, no qual se utilizaram sensores para monitorar a entrada e a saída de água e ar no sistema, sendo composto por dois reservatórios. Um deles armazena água para a circulação na tubulação hidráulica montada e outro armazena a água total do sistema. O controle do nível de água nos reservatórios é feito por sensores ultrassônico e potenciométrico. Um rotâmetro é usado para estimar o volume total da água que entra no sistema a partir da leitura de sua vazão volumé- trica. Resultados: os resultados obtidos mostraram que o hidrômetro tem uma sensibilidade ao fluxo de ar que não pode ser desprezada e chega a medir até 44% de ar na mistura ar-água. O erro entre o volume estimado de água pelo rotâmetro e o que é lido no hidrômetro foi de 3,7 litros. Conclusões: o hidrômetro é significantemente sensível à presença de ar nas tubulações hidráulicas residenciais, sob as condições normais de uma vazâo nominal de aproximadaemnte 1,5 m3 /h

    Tissue characterisation using an impedance spectrosopy probe

    No full text
    Available from British Library Document Supply Centre- DSC:DXN058806 / BLDSC - British Library Document Supply CentreSIGLEGBUnited Kingdo

    II Latin American Conference on Bioimpedance

    No full text
    This volume presents the proceedings of CLABIO 2015 - II Latin American Conference on Bioimpedance, held in Montevideo, Uruguay - September 30 - October 02, 2015. The works cover a broad range in Biomedical Engineering and Computing, Medical Physics and Medical Sciences, Environment, Biology and Chemistry. The topics are: ·Bioimpedance Applications ·Bioimpedance Instrumentation ·Body and Tissue Composition ·Cell Culture and Cell Suspension ·Electrical Impedance Tomography ·Electrode Modelling ·Magnetic Induction - Electrical Impedance Tomography ·Magnetic Resonance - Electrical Impedance Tomography ·Nonlinear Phenomena ·Organ and Tissue Impedance ·Plant Tissue Impedance ·Skin Impedance Modelling ·Technological Advances in Bioimpedance ·Theory and Modelling

    Tecnologias vestíveis para monitoramento de pacientes com COVID19 em cuidados domiciliares: revisão sistemática

    No full text
    Os sensores vestíveis são uma tecnologia emergente para monitorar sinais vitais, tendo a vantagem de reduzir o desconforto e interferir amigavelmente nas atividades diárias do paciente. O foco deste artigo é revisar as tecnologias vestíveis publicadas usadas para monitorar sinais biomédicos em pacientes infectados por coronavírus. Seis tipos diferentes de mecanismos de busca foram utilizados. Os artigos foram selecionados e validados por meio dos critérios da ferramenta AMSTAR2, a fim de verificar a qualidade desta revisão. 21 artigos foram selecionados entre 2016 e 2021 e tabulados de acordo com o tipo de tecnologia, abordagem de processamento e sinais monitorados. Os artigos são apresentados e uma ampla discussão traz sua aplicabilidade, eficácia e desafios para o acompanhamento domiciliar. O artigo chama a atenção para a necessidade de mais investimentos em biossensores vestíveis para monitoramento domiciliar, principalmente devido ao atual cenário pandêmico. Pode-se concluir que os sensores do tipo homecare necessitam de mais investigações em termos de sua eficiência em relação às abordagens padrão ouro de monitoramento domiciliar de pacientes com COVID-19

    Tecnologias vestíveis para monitoramento de pacientes com COVID-19 em cuidados domiciliares: revisão sistemática

    No full text
    Os sensores vestíveis são uma tecnologia emergente para monitorar sinais vitais, tendo a vantagem de reduzir o desconforto e interferir amigavelmente nas atividades diárias de qualquer paciente. O foco deste artigo é revisar as tecnologias vestíveis publicadas usadas para monitorar sinais biomédicos em pacientes infectados por coronavírus. Seis tipos diferentes de mecanismos de busca foram utilizados. Os artigos foram selecionados e validados por meio dos critérios da ferramenta AMSTAR 2, a fim de verificar a qualidade desta revisão. Foram selecionados 21 artigos, publicados no período temporal de 2016 a 2021, e tabulados de acordo com o tipo de tecnologia, abordagem de processamento e sinais monitorados. Os artigos selecionados são amplamente discutidos com base na aplicabilidade, eficácia e desafios da tecnologia para o acompanhamento domiciliar. Este artigo chama a atenção para a necessidade de mais investimentos em biossensores vestíveis para monitoramento domiciliar, principalmente devido ao atual cenário pandêmico. Pode-se concluir que os sensores do tipo homecare necessitam de mais investigações em termos de sua eficiência em relação às abordagens padrão ouro de monitoramento domiciliar de pacientes com COVID-19.</p
    corecore